Other faults
What if ... Possible fault Solution
The program
runs too long or
stops.
In some cases "Clean out airways" is displayed. See
"Settings - Supervisor level - Clean the airways". Open and
close the dryer door.
The air supply is
insufficient.
Open a window or door to
increase the air flow.
The lint filter is clogged
with lint.
Remove the lint.
The exhaust hose or the
connection is clogged with
lint.
–
Check the exhaust parts
regularly (e.g. wall vent duct,
louvered wall vent, bends,
etc.) for air permeability.
– Remove the lint.
The laundry was not spun
sufficiently in the washer.
Spin laundry thoroughly before
drying.
The dryer has over-loaded. Regard the maximum load size
per program.
Metallic zippers prevent a
correct measurement of
the laundry’s residual
moisture.
– Open the zippers of the
laundry before drying.
If the problem persists, dry
items with long zippers using
the "Warm air" program.
The laundry is
not dry enough.
The load contained too
many dissimilar items (size
and fabrics.)
–
Continue drying using the
"Warm air" program.
–
See the "Program Guide" for
suitable programs.
Frequently asked questions