Kenmore Clothes Dryer Clothes Dryer User Manual


 
GROUNDINGINSTRUCTIONS
Thisappliancemustbegrounded.
Intheevent of malfunction or break-
down, grounding will reduce the risk
of electric shock by providing a path
of least resistance for electric current.
The power supply cord must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
WARNING: improper connection of the
equipment-grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or serviceman
if your are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug on the power
supply cord. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
STEP 1. Disconnect power.
STEP 2. Remove hold-down screw
and terminal block cover.
H01d-d0wnscrew
Terminalblosksever
STEP 3. Attach a 3/4-inch, U.L.-listed
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with dryer cabinet and be in a
horizontal position. Put the power supply
cord through the strain relief.
STEP 4. Loosen or remove terminal block
screws. Connect the neutral wire (white
or center) of power supply cord under
the center screw of the terminal block.
STEP 5. Connect the other two wires
to outer terminal block screws. Securely
tighten all electrical connections.
External ground Center silver-colored
connector _ 2rminal blockscrew
(white)
Neutral / III \
grounding wire _ "-
(green/yellow) 3/4-inch,
U.L.-listed
strain relief
3=Wire Connection with
Frame-Grounding Conductor
STEP 6. Tighten the strain relief screws.
STEP 7. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
If local codes do not permit the
connection of a frame=grounding
conductor to the neutral wire,
see the instructions on page 17.
Otherwise, proceed with installation
on page 23.
I4