Kenmore 3405594 Washer/Dryer User Manual


 
CHECKING FOR AIR FLOW
OBSTRUCTION
From time to time, you may find it helpful
to check your laundry center and exhaust
system for proper air flow. Poor air flow
can result in longer drying times.
To check for air flow obstruction:
STEP 1. Check to ensure nothing is
blocking ventilation slots on laundry
center rear panel.
STEP 2. Inspect exhaust hood. It should
not be blocked or obstructed.
REMOVING ACCUMULATED LINT
Lint can gather inside the exhaust
vent or dryer and be fuel for a fire. Lint
should be removed every 2 to 3 years,
or more often, depending on dryer usage.
Cleaning should be done by a qualified
service person.
To remove accumulated lint from
exhaust vent:
STEP 1. Disconnect exhaust vent from
the laundry center.
STEP 2. Clean one section of vent at
a time until you reach the exhaust hood.
To clean out lint, you can use the hose
attachment on your vacuum or, use a
pole or wire with a feather duster or rag
attached.
STEP 3, Reconnect vent as described
in the "INSTALLATION INSTRUCTIONS"
of this Owner's Manual.
To remove accumulated lint from
inside the dryer:
Electrical Shock Hazard
Disconnect power before cleaning.
Replace all panels before operating,
Failure to follow these instructions
can result in death or electrical
shock.
STEP 1. Disconnect power.
STEP 2. Remove back panel by removing
the screws along the frame.
STEP 3. Remove lint from the dryer base
and from top of gas funnel with dusting
brush or vacuum cleaner attachment.
\
\
\
\
\
STEP 4. Replace back panel;
reconnect and level laundry center
again, if necessary.
52