Hotpoint NLL113 Clothes Dryer User Manual


 
13
Rough-In Dimensions
Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting
that will not support combustion. Metal ducting
must be 4(10.16 cm) in diameter with no
obstructions. Rigid metal duct is preferred.
If dryer is exhausted through the floor, the
exhaust system MUST NOT terminate beneath the
mobile home. Termination MUST be securely
fastened to the mobile home structure.
When installing a dryer into a mobile home,
a provision must be made for outside make-up
air. Provide an opening with a free area of at
least 25 square inches for introduction of outside
air into the dryer room.
Gas dryers MUST be fastened to the floor
using Mobile Home Installation Kit
Pub. No. 14-D346-33.
See the Exhaust System Requirements section
for other important venting information.
Installation MUST conform to current
Manufactured Home Construction & Safety
Standard (which is a Federal Regulation Title
24 CFR—Part 32–80) or, when such standard is
not applicable, with American National Standard
for Mobile Homes, ANSI/NFPA No. 501B.
The dryer is designed under ANSI Z 21.5.1
for HOME USE only.
6
5
4
3
2
1
Mobile Home Installation
26 7/8
(68.3 cm)
47 1/2
(120.7 cm)
43 5/8
(110.7 cm)
2 9/16
(6.5 cm)
13 1/2
(34.4 cm)
36
(91.5 cm)
Door open
90˚
4 3/8
(11.1 cm)
Optional
vent knockout
27
(68.6 cm)
Electrical connection
3/8(0.96 cm) Dia.
gas pipe
1(2.54 cm)
3 3/4
(9.5 cm)
3 3/4
(9.5 cm)
REAR VIEW
SIDE VIEW
Correct
Incorrect
Do
Do
Do
Dont
Dont
Dont
Servicing – Consideration must be given to provide adequate clearances for installation and servicing.
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions