5. Use the handle to pull the heat exchanger
out of the base and carry it horizontally to
prevent any remaining water from spilling.
6. To empty the heat exchanger, hold verti-
cally over a washing-up bowl.
Caution! Do not use sharp objects to
clean. The heat exchanger could
develop leaks.
7. Clean heat exchanger.
It is best to use a brush or to rinse thor-
oughly with a hand-held shower.
8. Replace heat exchanger and lock into
place (turn both lock washers outwards
until they snap into place).
9. Close door in plinth.
The appliance will not operate if the
HEAT EXCHANGER indicator is still lit.
Caution! Never operate the dryer
without the heat exchanger.
Cleaning the drum
Caution! Do not use abrasives or steel
wool to clean the drum.
Lime in the water or cleaning agents may
form a barely visible lining on the inside
of the drum. The degree to which the
laundry has been dried is then no longer
detected reliably. The laundry is damper
than expected when removed from the
appliance.
Use a standard domestic cleaner (e.g. vine-
gar-based cleaner) to wipe down the inside
of the drum and drum ribs.
Clean control panel and housing
Caution! Do not use furniture cleaners
or aggressive cleaning agents to clean
the machine.
Use a damp cloth to wipe down the control
panel and housing.
What to do if ...
Troubleshooting by yourself
If during operation, the error code E plus
number or letter) appears on the multi-dis-
play: Switch the appliance off and on again.
Reset programme. Press the START/PAUSE
button. If the error appears again, please
contact the Customer Care Department,
stating the error code
Problem Possible cause Remedy
Dryer does not work.
Mains plug is not plugged in or fuse
is not working correctly.
Plug in at mains socket. Check fuse
in fuse box (domestic installation).
Loading door is open. Close loading door.
Have you pressed the START/
PAUSE button?
Press the START/PAUSE button
again.
IronAid programme does
not start. the
water
tank indicator lights up.
Water tank is empty. Fill water tank.
Recirculation valve is closed (OFF
position)
Turn the recirculation valve to ON
position.
20 electrolux