© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9
AJ1032
Operation
Operating Controls
Figure 2
To avoid possible serious injury, BEFORE
operating press, ALL personnel MUST be
trained on safe operation.
W338
WARNING
To avoid possible serious injury, ALWAYS
read and become familiar with operating
instructions before operating press.
W339
WARNING
SCR95N
4
2
1
5
6
3
Control Function Description
1. Right CLOSE pushbutton When pressed simultaneously with left CLOSE
pushbutton (Item 6), closes press head. Must be
held until head is fully closed.
Press to actuate.
2. Pressing TIME selector knob Determines amount of time head remains
closed when timer switch (Item 4) is ON.
Set to desired time.
3. Air Inlet Assembly including
regulator, gauge, lubricator and
downstream air relieving
shut-off and lockout valve
REGULATOR: Reduces supply air pressure to
operating air pressure (80 psi).
Adjust air pressure regulator so operating
air pressure is 80 ± 5 psi.
DOWNSTREAM AIR RELIEVING
SHUT-OFF AND LOCKOUT VALVE: Turns
air supply to press on and off. Exhausts air
from press when in the off position. Capable of
being locked in off position.
Turn knob to on position to supply air to
press. Turn knob to off position to shut
off air supply to press and simultaneously
exhaust air from machine.
4. Timer ON/OFF switch Turns timer ON or OFF. Set to desired position.
5. OPEN pushbutton Opens pressing head. Overrides both CLOSE
pushbuttons and electric timer.
Press to actuate.
6. Left CLOSE pushbutton When pressed simultaneously with right
CLOSE pushbutton (Item 1), closes press head.
Must be held until head is fully closed.
Press to actuate.
NOTE: If EITHER CLOSE pushbutton is released BEFORE head is fully closed and pressing pressure is
applied, head will return to a fully open position.
Table 1