American Dryer Corp. ML-96HS Clothes Dryer User Manual


 
22
2. Technical Gas Data
a. Gas Specifications
b. Gas Connections
Inlet connection ------------ 1" inch N.P.T.
Inlet supply size ------------ 1" inch N.P.T. (minimum)
Btu/hr input (per dryer) ----- 310,000
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column
(W.C.) pressure.
Type of Gas
Natural
Manifold Pressure* 3.5 inches W.C.
Inline Pressure 6.0 - 12.0 inches W.C.
* Measured at gas valve pressure tap when gas valve is on.
Type of Gas
Natural
Model
Number
BTU Per
Hour
Rating
Qty. D.M.S.* Part Number
ML-96HS 350,000 3 #10 140836
* D.M.S. (Drill Material Size) equivalents are as follows:
Natural Gas .. #10 = .1935