FIRE SUPPRESSION SYSTEM (F.S.S.)
F.S.S. In Action
The exclusive Fire Suppression System (F.S.S.) will extinguish fires that may start in the drying basket (tumbler).
A series of sensors positioned throughout the basket (tumbler) and interfaced with the microprocessor controller
(computer) will trigger the F.S.S. water jet(s) to quickly extinguish the flames. The water jet(s) remain on for 2
minutes and will automatically activate again if a fire condition remains or reignites. While the water jet(s) are
activated, the basket (tumbler) will jog to move the water throughout the load. The microprocessor controller
(computer) will display until the dryer is attended to, that the system was activated.
BEFORE YOU START!
CHECK LOCAL CODES AND PERMITS
Call your local water company or the proper municipal authority for information regarding local codes.
IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified
professional to assure that the plumbing installation is adequate and conforms to local,
state, and federal regulations or codes.
IMPORTANT: It is the installation or owners responsibility to see that the necessary or required
water, water pressure, pipe size, or connections are provided. Manufacturer assumes
no responsibility if the F.S.S. is not connected, installed, or maintained properly.