American Dryer Corp. CG20 Clothes Dryer User Manual


 
450261-2 www.amdry.com 7
GAS VALVE REMOVAL:
Be sure to shut off the gas main and then proceed
to remove electrical connections and screws
indicated. Disconnect union and U-Bolt located just
behind the union and the oven base. The U-Bolt is
more easily accessed through the rear of the dryer.
The gas valve and burner orifice can now be pulled
out through the front of the dryer.
When reinstalling the gas valve be sure to align the
orifice with the opening in the burner tube bracket.
Misaligning and forcing valve inward can drive the
opposite end of the burner tube up against the
flame-probe elements.
OVEN REMOVAL:
The oven can be removed with or without the gas
valve in place.
Be sure to shut off the gas supply to the dryer. The
back guard, heat duct, and lower front panel must
be removed. Remove the gas valve electrical
connections and remove the lint box / blower
assembly. Remove the five screws (shown lower
right) that are holding the burner to the rear bulkhead.
Remove the two oven base nuts. With the lint box
out of the way, the oven can be tilted on its side and
pulled out through the front of the dryer.