American Dryer Corp. ADG-530D II Clothes Dryer User Manual


 
48
8. Failed microprocessor controller (computer) temperature sensor...temperature calibration is inaccurate.
9. Failed microprocessor controller (computer)...temperature calibration is inaccurate.
10. Lint accumulation in location exhaust system.
S. Condensation on main door glass...
1. Too long, undersized, or improperly installed ductwork.
2. Exhaust back draft damper is stuck open or partially open.
3. Restriction in exhaust ductwork.
T. Dryer is making scraping noise at basket (tumbler) area...
1. Check for object(s) caught in the basket (tumbler) wrapper area.
2. Basket (tumbler) is out of alignment...
a. Check both the vertical alignment and lateral alignment.
b. Check gap between the front panel and the basket (tumbler) front...setscrews may have come loose
and basket (tumbler) walked forwards or backwards.
3. Loose or broken basket (tumbler) tie rod.
4. Broken basket (tumbler) support.
U. Excessive noise and/or vibration...
1. Dryer is not level.
2. Motor (impellor/fan) is out of balance or broken.
3. Loose basket (tumbler) tie rod.
4. Basket (tumbler) is out of adjustment, or adjustment bolts (hardware) are loose.
5. Loose motor or motor mount assembly.
V. Basket (tumbler) turns too fast (as opposed to other baskets [tumblers])...
1. Foreign object(s) caught between basket (tumbler) belt and motor shaft.