IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.
Make-up air that is contaminated by dry cleaning solvent fumes will result in
irreparable damage to the motors and other dryer components.
IMPORTANT: Make-up air openings should not be located near ductwork exhaust outlets. If the
make-up air opening(s) are too close to the exhaust outlet, lint and fumes may be
drawn back into the dryer through these openings.
NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.
It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are
acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to
ALL
the dryers. The dryer must be installed with provisions for adequate combustion and make-up air supply.
EXAMPLE: For a bank of eight (8) dryers, a total make-up air opening of 16 square feet (1.49 square
meters) is required. Two (2) openings measuring 2 feet by 4 feet (0.61 meters by 1.23
meters) 16 square feet (1.49 square meters) is acceptable.
Allowances must be made for remote or constricting passageways or where dryers are located at excessive