H. STEAM INFORMATION
It is your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that
the installation is adequate and conforms to local and state regulations or codes.
IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in
component failure, which will VOID THE WARRANTY.
NOTE: The ADS-81 II is manufactured with a pneumatic (piston) damper system, which requires an
external supply of clean, dry, and regulated air (80 PSI +/- 10 PSI [5.51 bars +/- 0.68 bars]).
Refer to Steam Damper Air System Connections, Section H, item 3.
IMPORTANT: STEAM PH LEVEL – The normal PH level for copper type steam coils must be
maintained between a value of 8.5 to 9.5. For steel type steam coils, the PH level
must be maintained between a value of 9.5 and 10.5. These limits are set to limit the
acid attack of the steam coils.
1. Steam Requirements, High Pressure
a. Inlet------1-inch supply line connection – qty. one (1) at top manifold.
b. Return ---1-inch return line connection – qty. one (1) at bottom manifold.
2. Installation Instructions
To insure that an adequate supply of steam is provided, be sure that the steam supply and steam return lines
are sized and laid out as stipulated in this manual. Inadequate steam supply and steam return lines or
improper steam plumbing will result in poor performance and can cause component failure. Clean, dry, and
regulated steam must be provided to the dryer.
IMPORTANT: Steam coil failure due to water hammer by wet steam VOIDS THE WARRANTY.
a. The pressure of the condensate in the steam supply will cause water hammer and subsequent heat
exchanger (steam coil) failure. The steam supply connection into the main supply line must be made
with a minimum 12-inch (30.48 cm) riser. This will prevent any condensate from draining towards the
dryer.
Operating Steam Pressure
Maximum 125 psig 861.84 kPa
Minimum 100 psig* 689.47 kPa
Heat Input (Normal Load) 11 Bhp
Consumption (Approximate) 375 lbs/hr 170.09 kg/hr
Shaded areas are stated in metric equivalents
* Minimum operating pressure for optimum results.