American Dryer Corp. AD-81 II Clothes Dryer User Manual


 
11
B. UNPACKING/SETTING UP
1. Inside the basket (tumbler) of this dryer is an exhaust
transition piece that must be installed on the outlet of
the exhaust before any further venting is connected. To
do this, follow the procedures listed below:
a. Remove the exhaust transition piece from the basket
(tumbler) and place it on the exhaust outlet.
b. Using the screws provided, secure the exhaust
transition piece to the dryer.
NOTE: It is recommended that this joint be taped
as well as ALL other duct joints to prevent
moisture and lint from escaping into the
building.
2. Leveling Dryer
The dryer is equipped with four (4) leveling legs, one (1)
at each corner of the dryer base. Two (2) are located in
the rear of the dryer base, and two (2) are located in the
lint chamber. To increase bearing life and improve
efficiency, the dryer should be tilted slightly to the rear.
WARNING
An exhaust duct transition piece is shipped inside of the dryer’s
tumbler and MUST be installed on the dryer’s
exhaust duct, with the hardware provided, BEFORE
location venting is connected to the dryer.
THIS EXHAUST DUCT TRANSITION PIECE
MUST BE INSTALLED FIRST!
Failure to observe this installation requirement may result in
damage to the dryer, create a FIRE HAZARD and will VOID
the manufacturer’s warranty.
012999JEV-GS/cj P/N: 114092
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint build up.