American Dryer Corp. AD-758 Clothes Dryer User Manual


 
18
To Replace Microprocessor Temperature Sensor Probe
1. Discontinue electrical power to the dryer.
2. Remove lint drawer. Remove two (2) screws securing lint
door and remove lint door.
3. Remove microprocessor sensor bracket assembly from the
dryer.
a. Disconnect sensor bracket harness connector.
b. Loosen the two (2) Phillips head screws securing bracket
assembly to the dryer and remove bracket from dryer.
NOTE: DO NOT remove screws.
4. Disassemble sensor probe from bracket assembly by removing the top push-on fastener securing the probe
from bracket. Use a small screwdriver to slowly pry the fastener off.
5. Disconnect the two (2) orange wires from the high heat (225º F [107º C]) thermostat, and remove modular
bracket connector, wires, and probe from bracket assembly.
6. Install new sensor probe assembly (ADC P/N 880251) by reversing procedure.
7. Reestablish electrical power to the dryer.
NOTE: If, when power is reestablished, the computer display reads “dSFL,” check for a loose
connection in the wiring.
B. IGNITION CONTROLS
To Remove Spark Ignitor (refer to the burner illustration)
1. Discontinue electrical power to the dryer.
2. Disconnect high voltage (HV) connector and
flame probe connection from ignitor.
3. Disassemble ignitor from burner by removing
the two (2) self-tapping screws.
4. Reverse procedure for installing new ignitor/flame-probe.