American Dryer Corp. AD-758 Clothes Dryer User Manual


 
9
NOTE: Pressing keyboard (touch pad) “A,” “B,” “C,” “D,” or “F” will also start the dryer. Six (6)
preprogrammed drying cycles (“A” through “F”) have been stored in the computer’s memory.
(Refer to the Computer Operator’s Manual for details.)
3. Make a complete operational check of ALL the operating controls to assure that the timing is correct,
temperature selection switches are functioning, etc.
4. Make a complete operational check of ALL safety-related circuits: door switch(es), hi-limit thermostat, sail
switch, cycling thermostats, etc.
5. For gas dryers a gas pressure test should be taken at the gave valve pressure tap of each dryer to assure
that the water column (W.C.) pressure is correct and consistent.
NOTE: Water column pressure requirements (measured at the pressure tap on the gas valve body):
Natural Gas------------------- 3.5 Inches (8.7 mb) Water Column.
Liquid Propane (L.P.) Gas ---- 10.5 Inches (26.1 mb) Water Column.
6. If computer program changes are required, refer to the Phase 5 OPL Operator’s Manual (ADC P/N
112147) for details.
7. The dryer should be operated through one (1) complete cycle to assure that no further adjustments are
necessary and that ALL components are functioning properly.
8. Check the electric service phase sequence. While the dryer is operating, check to see if the blower wheel
is rotating in the proper direction. Looking from the front, the blower wheel should spin in the clockwise
(CW) direction. If so, the phasing is correct. If the phasing is incorrect, reverse two (2) leads at connections
L1, L2, or L3 of power supply to the dryer.