American Dryer Corp. AD-670 Clothes Dryer User Manual


 
39
CALL FOR SERVICE - Indicates a board failure.
FRONT DOOR NOT CLOSED - A front door is open when it should be closed.
REAR DOOR NOT CLOSED - A rear door is open when it should be closed.
CHECK CONTROL POWER - Indicates control power is off.
EXHAUST HIGH TEMP FAULT - Indicates the temperature in the basket (tumbler) is above 225º F (107º C).
LINT DRAWER OPEN - Indicates the lint drawer is open and needs to be closed.
DRY ENABLE FAULT - Indicates the dryer is not level and ALL doors are closed. Not ready to start drying.
FRONT NOT DOWN - Dryer is tilted back.
REAR NOT DOWN - Dryer is tilted forward.
BASKET (TUMBLER) OVERLOAD FAULT - Indicates the basket (tumbler) overload has tripped open.
FAN OVERLOAD FAULT - Indicates the fan overload has tripped open.
EXHAUST HI-LIMIT FAULT - Indicates the temperature disk in the exhaust has opened.
FRONT SAIL SWITCH CLOSED FAULT - Front sail switch is closed and should be open.
FRONT SAIL SWITCH OPEN FAULT - Front sail switch is open and should be closed.
REAR SAIL SWITCH CLOSED FAULT - Rear sail switch is closed and should be open.
REAR SAIL SWITCH OPEN FAULT - Rear sail switch is open and should be closed.
FAN CONTACTOR FAULT - The fan contactor was not pulled in.
FRONT BURNER HI-LIMIT FAULT - Indicates the temperature disk in the front burner has opened.
REAR BURNER HI-LIMIT FAULT - Indicates the temperature disk in the rear burner has opened.
FRONT BURNER VALVE FAULT - Indicates front gas valve is not working or no gas is turned on or flameout.
REAR BURNER VALVE FAULT - Indicates rear gas valve is not working or no gas is turned on or flameout.
FRONT BURNER IGNITION CONTROL FAULT - Front ignition module is not working or failure to ignite.
REAR BURNER IGNITION CONTROL FAULT - Rear ignition module is not working or failure to ignite.
ROTATION FAULT - Indicates the basket (tumbler) is not rotating.
BAD PROBE - Indicates the temperature probe is open or shorted.
LOW VOLTAGE FAULT - Indicates power has dropped below the operating values and will shut down.