57
SECTION IX
REVERSING TIMER SPIN/DWELL
ADJUSTMENTS
Dual timer models with "reversing option" have an electric reversing timer in the electric service box which is
located in the upper rear area of the dryer.
Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on
the electronic timer (as noted in the illustration below).
T
IMING
L
EGEND
SPIN TIME
Switch Position Number 1 2 3 4 5
Time in Seconds* 30 60 90 120 150
D
WELL (STOP) TIME 12345
Switch Position Number 5 6 8 10 12