American Dryer Corp. AD-30V Clothes Dryer User Manual


 
51
2. Impellor (fan/blower) out of balance ...
a. Excessive lint build up on impellor (fan/blower).
b. Failed impellor (fan/blower).
3. Loose basket (tumbler) tie rod.
4. Basket out of adjustment, or adjustment bolts (hardware) are loose.
5. Failed basket (tumbler) support.
6. Loose motor mount.
7. Failed idler and/or tumbler bearings.
8. V-belt(s) either too tight or too loose.
U. Main burners are burning with a yellow flame (for GAS MODELS ONLY)...
1. Burner air shutters are out of adjustment.
2. Insufficient make-up air.
3. Dust and/or lint in burner.
4. Insufficient gas pressure.
DUAL TIMER MODELS
A. Dryer will not start...both drive and blower motors not operating (indicator light is off)...
1. Dryer control circuit fuse is blown.
2. Open at location...service main fuse or circuit breaker.
3. Failed push to start relay.
4. Failed door switch and/or circuit.
5. Failed heat timer.
6. Failed dual timer relay.
B. Drive motor (only) not operating...
1. Failed drive motor contactor.
2. Failed reversing timer (for Reversing Models ONLY).
3. Failed drive motor.