2. Technical Gas Data
a. Gas Specifications
Shaded areas are stated in metric equivalents
* Measured at gas valve pressure tap when the gas valve is on.
b. Gas Connections:
Inlet connection --------------- 3/4” M.P.T.
Inlet supply size---------------- 3/4” Pipe (minimum)
Btu/hr input (per dryer) ------ 160,000 (40,320 kcal/hr)
Btu/hr input (per pocket) ----- 80,000 (20,160 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ........................ #18 = 0.1695” (4.3053 mm).
Liquid Propane Gas ......... #38 = 0.1015” (2.5781 mm).
** Per pocket/basket (tumbler).
*** Includes parts for both baskets (tumblers).
TYPE OF GAS
NATURAL LIQUID PROPANE
Manifold Pressure* 3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
In-Line Pressure 6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
27.4 mb
TYPE OF GAS
Liquid
Propane
Conversion Kit
Part Number***
Btu/hr
Rating**
kcal/hr
Rating
Natural Liquid Propane
Qty.** D.M.S.* Part No. Qty.** D.M.S.* Part No.
80,000
20,160
1 #18 140829 1 #38 140814 882396