Alliance Laundry Systems UW60B2 Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
19
F232168
NOTE: ON appears ONLY where motor control
outputs are on (otherwise they are off). Outputs
referenced are on control unit fuse board. Outputs
are as labeled on the fuse board.
NA – Not Applicable
Table 2 (Continued)
Pause 5 seconds, then Reverse
wash speed – 60 seconds, pause
several seconds before entering
drain (next step)
Display shows ‘rEv’
Outputs: Motor operates wash speed reverse; drain closed
Drain (cannot advance to spin
here)
For 2 speed models
: Display flashes “drAI”/“For” (keypad RINSE LED on)
For variable-speed models
: Display flashes “drAI”/“For” while operating in low speed
forward; then flashes “drAI”/“dISt” while operating at distribution speed.
If balance fails, repeats the “drAI”/“For” then “drAI”/“dISt” sequence above and balance
indicator is on during “drAI”/“For” message (rebalance attempt). Tries up to 10 times in
TEST cycle, then aborts test cycle.
Outputs: Drain closed for first part of step (less than 20 seconds), then drain off.
2 speed models
: Wash speed forward
Variable-speed
: Forward during “drAI”/“For”; distribution during “drAI”/“dISt”.
Spin: 3 minutes For 2 speed models: display shows “SPIn” (keypad SPIN LED on)
For variable-speed models: display shows “HI 1” (keypad SPIN LED on)
Outputs: Spin (low spin for variable-speed – refer to motor chart below)
Highest Spin speed (variable-
speed models ONLY):
2minutes
For 2 speed models: this step is skipped, goes to coast (the next step)
For variable-speed models: display shows “HI 2” (keypad SPIN LED on)
Outputs: Highest spin speed selected (refer to motor chart below)
Coast Displays “SdLY” (spin delay coast)
Outputs: All off
Stop routine Display shows “01” (1 minute remaining). Agitates briefly then unlocks the door, shows
“doNE” while sounding the buzzer 10 seconds; “doNE” shows until door is opened
(DOOR LED on while showing “doNE”, meaning “door ready to open”).
Motor Speed Chart
2 Speed Motor Outputs
Fwd Rev Spin
Motor off (no rotation)
Wash speed forward ON
Wash speed reverse ON
Distribution (variable-speed ONLY) NA NA NA
Spin (low spin speed “HI 1” for variable-speed) ON
Highest spin (“HI 2” – variable-speed ONLY) NA NA NA