Alliance Laundry Systems UW60B2 Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
F232168
14
Heated Models Only
Display shows temperature in degrees F or C. Display
will show degrees F if configured for “FAr” in Setup
Mode, or degrees C if configured for “CEL” in Setup
Mode. Range is 80°F to 205°F, or 00F (no heat for
segment), or 27°C to 95°C, or 00C (no heat for
segment).
Press the (∧) key to increase, or (∨) key to decrease
temperature in one-degree increments. The control
will energize heat and pause cycle timing for up to
50 minutes until the programmed temperature is first
reached.
NOTE: If temperature not reached after
50 minutes, control resumes cycle.
After cycle resumes, control will attempt to maintain
programmed temperature if it senses water in the
machine.
NOTE: Temperature display applies ONLY if
machine is configured for “HEAt” in Setup Mode.
Machine must be equipped with electric or steam
heat and a temperature sensor. If configured for
“noHt” (no heat capability) in Setup Mode,
temperature display does not appear in the
segment. After temperature setting, control will
skip to “drAI”/“nodr” or Spin Time, depending on
version.
If display shows “drAI”/“nodr” during segment
programming, a drain step option can be selected.
Select “drAI” for a drain step followed by an optional
spin. Select “nodr” for no drain step. The machine will
proceed directly to the next segment if “nodr”. Change
the selection by pressing the (∧) or (∨) key. Press
START to continue.
If “drAI” is selected (or if your model does not provide
the option of selecting “drAI”/“nodr”), the display will
show “SPIn” one second, “tI
nE” one second, and then
the time for spin: “00” (no spin) or 30-240 seconds.
Change the selection by pressing the (∧) or (∨) key.
Press START to continue. Then enter the next segment
(USH2, USH3, USH4 or after USH4, the “rIN1”
segment). Refer to Rinse 1 – Rinse 4 section.
Rinse 1 – Rinse 4
NOTE: Programming a time other than “00” for
this step will make the RINSE indicator LED light
while this step is running, but not in Program
Mode.
The main display shows “rIN1” indicating you are in
the Rinse segment (number will represent Rinse cycle
selected 1-4). Press START key. Display shows the
time for agitation during the step: “00” (skips
segment) or 2-15 minutes. This is the time after the fill
and before the drain and does not include spin time.
Press the (∧) or (∨) key to alter the selection, or the
START key to continue.
Display shows “CFIL”, “HFIL”, “bFIL” or “EFIL” for
cold, hot, warm (both) or Extra Fill. Press the
(∧) or (∨) key to alter the selection, or the START key
to continue.
NOTE: Extra Fill (“EFIL”) possible only if
configured for “EFIL” in Setup Mode. If
configured, a third valve can be controlled.
Display shows “LO”, “
nEd”, or “HI” for low, medium,
or high water level, respectively. Press the (∧) or (∨)
key to alter the selection, or the START key to
continue.
Display shows “SUP0”, “SUP1”, “SUP2”, “SUP3”,
“SUP4”, “SUP5” (extra supply), “SUP6”, or “SUP7”
(supply 4 and extra supply together), indicating no
supply, supply 1, supply 2, supply 3, supply 4,
supply 5 (extra supply), supply 6 (supply 1 and 2
together), or supply 7 (supply 4 and extra supply 5
together). Press the (∧) or (∨) key to alter the
selection, or the START key to continue.
NOTE: “SUP5” and “SUP7” appear ONLY if
control is configured for “ESUP” (spare output set
up to operate as an EXTRA supply signal for
external chemical) in Setup Mode. If the alternate
function for the spare output is selected (“EFIL”),
the output will function as an additional fill valve
signal with a programmable water level. In this
case, extra supply function would NOT be
available.
NOTE: If programmed for “SUP2”, the ADD
BLEACH indicator LED light turns on and if set
up for “bEEP” (refer to Setup Mode section) the
buzzer sounds for the first 8 seconds that supply 2
is on.
Press the (∧) or (∨) key to alter the selection or START
key to continue.