Alliance Laundry Systems UW150PV Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Specifications and Dimensions
F232084
38
The terminal strip that furnishes the supply output
signal for the chemical injection supply pumps, is
located inside the control module at the rear. Access is
through the rear panel of the module.
Terminals SUPPLY 1 through SUPPLY 9 and
common provide 200 – 240VAC fused at 500mA.
These terminals may be used to provide signals to the
chemical injection system but must not be used to
provide power to the pump. Do not attempt to increase
fuse rating as this may cause damage to the washer-
extractor’s circuitry.
An external chemical injection system requiring 200 –
240VAC can be powered through LINE 1 and LINE 2
on the external supply terminal strip on UWPVQ, PVT
and PVX models. Any chemical injection system used
with UWPVN and UWPVP models must be powered
by a separate external power source.
Any injection system pump which requires 110VAC
must be powered by a separate external power
source.
Consult the chemical injection supply system
instructions for operational details.
Attempting to obtain 110VAC by using L1
or L2 with the common may damage
laundry machine circuitry and/or the
chemical injection system. Using a
240VAC power wire in the washer-
extractor and an earth ground to obtain
110VAC could cause microprocessor
problems.
SW028
CAUTION