Alliance Laundry Systems UW150PV Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Specifications and Dimensions
33
F232084
UWPV Pocket Hardmount
Electrical Specifications
Voltage Designation Standard Electric Heat
Model
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Breaker
AWG
mm
2
Full Load
Amps
Breaker
AWG
mm
2
35
N 440 – 480 50/ 3 3 4 15 14 2.5 25 30 10 6
P 380 – 415 50/ 3 3 4 15 14 2.5 22 30 10 6
Q 200 – 240 50/ 3 3 6 15 14 2.5 38 50 6 16
T 200 – 240 50/ 1 2 17 20 12 4 Not available in this voltage.
60
N 440 – 480 50/ 3 3 6 15 14 2.5 33 40 8 10
P 380 – 415 50/ 3 3 6 15 14 2.5 29 40 8 10
Q 200 – 240 50/ 3 3 12 15 14 2.5 66 80 3 25
T 200 – 240 50/ 1 2 14 30 10 6 Not available in this voltage.
X 200 – 240 50/
60
1 or
3
2 or
3
14 20 12 4 or 4 Not available in this voltage.
80
N 440 – 480 50/ 3 3 7 15 14 2.5 66 80 3 25
P 380 – 415 50/ 3 3 7 15 14 2.5 57 70 4 25
Q 200 – 240 50/ 3 3 13 20 12 4 99 110 1 50
10
0
N 440 – 480 50/ 3 3 7 15 14 2.5 66 80 3 25
P 380 – 415 50/ 3 3 7 15 14 2.5 57 70 4 25
Q 200 – 240 50/ 3 3 13 20 12 4 99 110 1 50
12
5
N 440 – 480 50/ 3 3 7 15 14 2.5 66 80 3 25
P 380 – 415 50/ 3 3 7 15 14 2.5 57 70 4 25
Q 200 – 240 50/ 3 3 13 20 12 4 132 140 2/0 70
15
0
N 440 – 480 50/ 3 3 8 15 14 2.5
NOT
AVA ILA B L E
P 380 – 415 50/ 3 3 8 15 14 2.5
Q 200 – 240 50/ 3 3 14 20 12 4
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 7