Specifications and Dimensions
F232084
18
Mounting Bolt Installation
Requirements (Approved
Foundations Only)
NOTE: If installing expansion bolts into an
elevated concrete foundation pad, the concrete
foundation pad should extend a minimum of 9
inches (229 mm) for UW35 machines or 12 inches
(305 mm) for UW60 - 150 machines out from the
machine base on all sides. Refer to Figure 5.
NOTE: The optional Premium Wet Clean Module
does not require permanent attachment to the floor.
A bolt kit consisting of eight bolts is available as an
option. UW35PV machines use 5/8-11 x 8 inch bolts.
UW60PV – UW125PV machines use 3/4-10 x 8 inch
bolts. UW150PV machines use 3/4-10 x 10 inch
grade 5 bolts. The bolts should be embedded in a
3500 psi (241 bar) minimum reinforced concrete floor
that is a minimum of 12 inches (30.48 cm) thick. Use
the mounting bolt layouts in Mounting Bolt Hole
Locations section.
On UW35PV – UW125PV machines, the threaded end
of the bolts should extend 2 inches (5.08 cm) above
the mounting surface. On UW150PV machines, the
threaded end of the bolts should extend 3 inches above
the mounting surface.
Refer to Figure 6 for a typical installation of individual
mounting bolts.
Figure 6
For new foundations a bolt-locator fixture or rebar
frame is available and a preferred option. This rigid
welded assembly made of reinforcing rod and
mounting bolts is designed to be embedded in
concrete. Refer to Figure 7.
Figure 7
PHM722N
1 Machine Frame Base
2 Grout
3 Cement or Structural Epoxy
PHM722N
1
2
2 in.
(51 mm)
8 in.
(203 mm)
0.75 in.
(19 mm)
3
PHM179N
1 Machine Frame Base
2 Mounting Bolt Threads
3 Grouting
4 Reinforcing Rod
PHM179N
1
2
3