Alliance Laundry Systems UF50PV Washer User Manual


 
Maintenance
48
F232058
Monthly (Continued)
Figure 29
4. Remove back panel and check overflow
hose and drain hose for leaks.
5. Clean inlet hose filter screen:
a. Turn water off and allow valve to cool,
if necessary.
b. Unscrew inlet hose and remove
filter screen.
c. Clean with soapy water and reinstall.
Replace if worn or damaged.
6. Unlock the hinged lid and check the
supply dispenser hoses and hose
connections.
7. Tighten motor mounting bolt locknuts and
bearing bolt locknuts, if necessary.
8. Use compressed air to clean lint
from motor.
9. Clean interior of machine, both basket and
shell, by wiping with a water-soaked
sponge or cloth.
10. Use compressed air to ensure that all
electrical components are free of moisture
and dust.
Quarterly
Note: Disconnect power to the machine
before performing the quarterly maintenance
procedures.
1. Tighten door hinges and fasteners,
if necessary.
2. Tighten anchor bolts, if necessary.
3. Check all painted surfaces for bare metal.
(Matching gray paint is available from
the manufacturer.)
If bare metal is showing, paint with
primer or solvent-based paint.
If rust appears, remove it with
sandpaper or by chemical means.
Then paint with primer or solvent-
based paint.
4. Clean steam filter, where applicable.
a. Turn off steam supply and allow time
for the valve to cool.
b. Unscrew nut.
c. Remove element and clean.
d. Replace element and nut.
5. Inspect suspension components for wear
or corrosion. Observe the operation of the
machine to ensure proper tension and
operation of the suspension system.
6. If the washer-extractor is equipped with
one of the tilt options, inspect fasteners
between the tilt mechanism and washer-
extractor for corrosion. Verify that the
fasteners are securely tightened.
Driven
Drive Pulley
Motor
Pulley
Straightedge