Wet Clean Processing
For wet clean processing, program the
standard test cycle to verify proper operation
of the wet clean system. (Refer to the Cabinet
Freestanding Operation/Programming
manual.)
Run the test cycle and verify that the wet clean
system is operating properly:
• Check plumbing connections for leaks.
• Verify that the Premium Wet Clean
Module pump is operating properly, and
that the rotation direction is
counterclockwise. If rotation direction is
incorrect, a qualified electrician may
reverse any two leads. See Step 6i of
Premium Wet Clean Module installation
section.
• Verify that the drain valve on the Premium
Wet Clean Module opens and closes
properly.
• Verify that the canister lid does not leak.
If problems arise during the control function
test, stop the washer-extractor and return to the
Premium Wet Clean Module installation
section for proper installation of components
and wiring.