Alliance Laundry Systems Stacked Drying Tumbler Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
33
M412060
Preventive Maintenance Instructions
Daily
Lint Removal
1. Unlock the lint drawer and remove it. Refer to
Figure 15.
2. Remove all accumulated lint in the lint
compartment area by tipping the drawer over a
garbage collection can or similar container.
3. Be sure the lint screen is not torn. If it is, replace
immediately. A torn screen allows lint to pass
from the tumbler to the ductwork system creating
a restriction to air circulation or adversely
affecting the recirculation function of the
tumbler. Both affect machine efficiency.
4. The lint screen is designed to completely cover
the entire opening in the angled section of the lint
drawer. Be sure that it does so. Excessive gaps
between the lint screen and the lint drawer allows
lint to pass into the ductwork system.
5. Wipe any accumulated lint from the lint drawer
compartment area. Failure to do so will allow a
buildup of lint in this area.
6. Reinstall the lint drawer, ensuring a tight fit and
lock.
IMPORTANT: Failure to lock lint drawer will
result in the tumbler not starting.
Monthly
Lubrication
Motor bearings, fan bearings, cylinder bearings and
cylinder roller bearings are pre-lubricated sealed
bearings and require no lubrication.
Lint Removal
Remove the exhaust duct from exhaust thimble and
remove lint. If excessive lint is evident at the thimble,
further disassemble the duct work and remove lint.
Also, remove blower housing assembly from cabinet
and remove any lint present in blower housing or on
fan.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
To reduce the risk of serious injury, do not
open the lint panel while the tumbler is in
operation. Before cleaning the lint screen,
open tumbler door and allow cylinder to
completely stop.
W410
WARNING