Installation Instructions
15
M412060
Combined Exhaust Manifold
Figure 4
VERTICAL EXHAUST INSTALLATION HORIZONTAL EXHAUST INSTALLATION
180°
Sweep Elbow
No Screen
or Cap
2 in (5.1 cm)
Minimum
Clearance
30 in (76.2 cm)
Minimum
Clearance
0 in
Clearance
Permitted
for First
4 in (10.2 cm)
12 in (30.5 cm)
Minimum
Clearance
0 in Clearance
Permitted
for First
4 in (10.2 cm)
2 in (5.1 cm)
Minimum
Clearance
No
Screen
or Cap
Wall
NOTE: Maximum length of
exhaust duct is 14 feet (4.3
meters) beyond manifold duct.
NOTE: Maximum length
of exhaust duct is
14 feet (4.3 meters)
beyond manifold duct.
Clearance permitted to combustible material
36 in (91.4 cm) recommended for maintenance purposes
24 in (61.0 cm) minimum
Wall
TMB2153N
12 in (30.5 cm)
Minimum
Clearance
Manifold
Duct
Manifold
Duct
0 in