Alliance Laundry Systems HF18VCV Washer User Manual


 
15
Operation
F232061
Display Indications
Display Meaning Display Meaning
FC 5
Program identification code (ROM). This
is an example only.
HFIL Hot fill
Lo Low water level
Hold Wait...power has just been turned on.
n
ed
Medium water level
PAY/(price)*
Pay (flashes alternately with start price if
“FLSH” SETUP option is enabled)
HI High water level
SUP0 No supplies
CY Cycle (followed by two-digit number) SUP1 Supply 1
tESt/CYC* Test cycle selected. SUP2 Supply 2
FAr Degrees Fahrenheit SUP3 Supply 3
CEL Degrees Celsius SUP5 Supply 5 (Supply 1 and 2)
Heat Auxiliary heat enabled. SUP6 Supply 6 (Supply 2 and 3)
noHt Auxiliary heat disabled. drAI/dISt* Distribution (load balancing before extract)
FLSH Flashing vend price enabled. drAI/For*
Drain step (low speed forward in test
cycle)
nFLS Flashing vend price disabled.
SPIn/tI
n
E*
Reads “SPIn” for one second, then
“tI
n
E” followed by time for spin.
Strt/A
n
t*
Start amount—flashes briefly before
showing vend price in SETUP mode
SdLY Spin coast delay
Con1/deno*
Coin 1 value—flashes briefly before
showing value of coin 1 in SETUP mode
STOP Stop routine
donE Cycle and stop routine have ended.
Con2/deno*
Coin 2 value—flashes briefly before
showing value of coin 2 in SETUP mode
HI 1 Low spin in test cycle.
HI 2 High spin in test cycle.
PrE Prewash segment (1st of 8 segments) bAL/FAIL* Balance routine failed during test cycle.
UASH Wash segment (2nd of 8 segments) SHUT/door* Door not properly closed.
FIL1 First fill (3rd of 8 segments)
CANt/OPEN*
Computer cannot unlock door after five
attempts.
FIL2 Second fill (4th of 8 segments)
FIL3 Third fill (5th of 8 segments)
FILL/STOP*
Programmed water level not reached after
30 minutes.
FIL4 Fourth fill (6th of 8 segments)
FIL5 Fifth fill (7th of 8 segments)
FULL
The computer detects low water level or
higher when none should be present.
FIL6 Sixth fill (8th of 8 segments)
AFIL Auxiliary fill dFLt Drive fault detected.
bFIL Warm fill (both hot and cold)
tSFL
Temperature sensor failure or temperature
out of range.
CFIL Cold fill
bLCH Add bleach
*Display indications separated by a slash represent an alternating display.