Programming
F232157
30
Table 4
(*) For certain 125 models, the RPM may display.
NOTE: ON appears ONLY where motor control
outputs are on (otherwise they are off). Outputs
referenced are on control unit fuse board. Outputs
are as labeled on the fuse board.
Table 5
NOTE: For variable-speed machines smaller than
C80, SPn1 and SPn2 are not the same speed.
Table 4 (Continued)
Pause 5 seconds, then
Reverse wash speed –
2 minutes, then pause
several seconds before
entering drain (next step)
Display shows “rEv”
Outputs: Motor operates wash speed reverse; drain closed
Drain (cannot advance to
spin here)
For 2 speed models
: Display flashes “drAI”/ “For” (keypad RINSE LED on)
For variable-speed models
: Display flashes “drAI”/ “For” while operating in low speed
forward; then flashes “drAI”/ “dISt” while operating at distribution speed.
If balance fails, repeats the “drAI”/ “For” then “drAI”/ “dISt” sequence above and balance
indicator is on during “drAI”/ “For” message (rebalance attempt). Tries up to 10 times in
TEST cycle then aborts test cycle.
Outputs: Drain closed for first part of step (less than 20 seconds), then drain off.
2 speed models
: Wash speed forward
Variable-speed
: Forward during “drAI”/ “For”; distribution during “drAI”/ “dISt”.
Spin – 3 minutes For 2 speed models:
display shows “SPn” (keypad SPIN LED on)
For variable-speed models:
display shows “SPn1” (keypad SPIN LED on)
Outputs: Spin (low spin for variable speed-see motor chart below)(*)
Highest Spin speed
(variable-speed models
ONLY) – 3 minutes
For 2 speed models:
this step is skipped (goes to coast, the next step)
For variable-speed models:
display shows “SPn2” (keypad SPIN LED on)
Outputs: Highest spin speed selected (see motor chart below)(*)
Coast Displays “SdLY” (spin delay coast)
Outputs: all off
Stop routine. Display shows “01” (1 minute remaining). Agitates briefly then unlocks the door, shows
“dOnE” while sounding the buzzer 10 seconds; “dOnE” shows for 20 more seconds.
(DOOR LED on while showing “dOnE”, meaning “door ready to open”).
Motor Speed Chart
Variable-speed motor control outputs –
applies only for variable-speed models
2 speed motor outputs
STF STR RH RM RL Fwd Rev Spin
Motor off (no rotation)
Wash speed forward ON ON ON
Wash speed reverse ON ON ON
Distribution (variable-speed ONLY) ON ON NANANA
Spin (low spin speed “SPn1” for variable-
speed)
ON ON ON ON
Highest spin (“SPn2” – variable-speed ONLY) ON ON ON NA NA NA
NA – Not Applicable