Installation
510963
18
Electrical Plug Connection
Three-Wire Plug
Figure 14
1. Remove access cover from rear of dryer.
Figure 15
2. Use a strain relief and insert end of power cord
through power supply hole.
Figure 16
D816I
1 3 Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)
4 Metallic or Non-Metallic Sheathed Cable
(Copper Wire Only)
5 Pigtail to Dryer (Refer to NOTE above)
2 30 Ampere Fuses or Circuit Breaker 6 Neutral
3 Neutral Wire 7 Terminal Block in Dryer
NOTE: The power cord (pigtail) is NOT supplied with
the electric dryer. Type of pigtail and gauge of wire
must conform to local codes and instructions.
The method of wiring the dryer is optional and subject
to local code requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.
1
3
5
6
7
4
2
PIGTAIL CONNECTION
DIRECT CONNECTION
L1 L2
L1 L2
INTERMEDIATE
SHUT-OFF BOX
(may or may not
be fused)
POWER SUPPLYPOWER SUPPLY
INTERMEDIATE
FUSE BOX (may
be omitted if
service entrance
box is fused)
WALL
RECEPTACLE
A typical
30-Amp
Three-Wire
Receptacle
NEMA Type
10-30R
120 ± 12
V.A.C.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: Use COPPER WIREonly.
Shorter than 15 ft. (4.5 m) – use 10 AWG
Longer than 15 ft. (4.5 m) – use 8 AWG
D695I
D696I