Installation
11
510963
Step 4: (Electric Dryer Only) Connect
Electrical Plug
For further assistance, refer to Section on Electrical
Requirements.
IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply
cord kit rated 240 Volts (minimum) 30 Amperes
and labeled as suitable for use in a clothes dryer.
Figure 6
Figure 7
NOTE: For more detailed information on
connecting three-wire or four-wire plugs, refer to
Section on Electrical Plug Connection.
NOTE: Four-wire cord is required for mobile
homes or where codes do not permit grounding
through neutral.
Figure 8
D275I
1 Typical Three-Wire Receptable
2 Power Cord (Three-Wire)
3 Strain Relief Nut
4 Strain Relief
D006I
1 Typical Four-Wire Receptacle
2 Power Cord (Four-Wire)
3 Strain Relief Nut
4 Strain Relief
1
2
3
4
THREE WIRE
1
3
4
2
FOUR WIRE
D679I
1 Ground to Neutral Wire
2 Neutral Terminal
3 “L2” Terminal
4 Center Wire (Neutral)
5 Strain Relief (Not supplied with dryer)
6 Ground Screw
7 “L1” Terminal
8 Ground Wire
NOTE: Dryer is shown with access cover removed for
illustration purposes only. NEVER operate dryer with
access cover removed.
D679I
1
2
3
6
THREE-WIRE CONNECTION
4
5
7
8