7. BUZZER SWITCH Activates the BUZZER CIRCUIT. When turned ON and TIMER
has reached 0, BUZZER will sound until BUZZER SWITCH is
turned OFF or TIMER is activated.
8. FILTER PUMP SWITCH ON causes the oil to be filtered / pumped back into the FRYPOT.
(ON - OFF) The POWER SWITCH (item 1) must be in the FILTER position for
the FILTER PUMP SWITCH to operate.
9. HI-LIMIT THERMOSTAT Provides over-temperature protection by de-energizing the
HEATING ELEMENTS if the oil temperature exceeds the factory-
set limit. RESET must be performed manually. Allow the oil to
cool below 300ºF (93ºC), then firmly press the red button on the
LOWER CONTROL PANEL until it resets (snaps).
10. TEMP. CONTROL Controls the oil temperature from 250ºF (121ºC) turned fully
THERMOSTAT counter-clockwise, to 375ºF (191ºC) fully clockwise.
11. DRAIN VALVE LEVER Opens and closes the DRAIN VALVE.
To OPEN, turn the handle counterclockwise (to vertical).
To CLOSE, turn the handle clockwise (to horizontal).
12. POWER OUTLET BOX Contains the electrical service connection terminal block.
13. OIL FILTER RESERVOIR Holds the filter screen, filter paper and filter paper holder.
14. FILTER PUMP MOTOR The FILTER PUMP MOTOR is equipped with an over-
RESET BUTTON heating protection device.
(located at the rear RESET must be performed manually. Allow the motor to
of the motor) cool for approx. 15 min., then press the red button.
15. BASKET Sits on the LIFT CRADLE and holds product to be cooked.
Raised and lowered by the LIFT CRADLE.
16. BASKET HANDLE Used to handle the BASKET when it is hot. REMOVE
FROM BASKET BEFORE ACTIVATING TIMER.
17. DRIP PAN Collects any liquids which accumulate on top of the fryer.
CAUTION: FIRE HAZARD / HOT OIL
THE HI-LIMIT THERMOSTAT IS A FIRE PROTECTION DEVICE.
If tripping persists, clean the space between the
hi-limit bulb and the element in order to enhance oil flow and facilitate reset.
Otherwise, contact your authorized Wells service agency for repairs.
DO NOT ATTEMPT TO BYPASS OR HOLD IN THE BUTTON OF THE
HI-LIMIT THERMOSTAT. A FIRE MAY RESULT.