A SERVICE OF

logo

6 Desktop Docking Cradle
MX6 Cradle Reference Guide E-EQ-MX6DKRG-D-ARC
Attach the Serial or USB Cable
Cables for the Desktop cradles are available in the following configurations:
RS-232 Cable – 26-pin to DB-9
USB Cable – USBA to USB
Only one cable can be connected to the desktop cradle at a time – either USB or RS-232.
Connect the DC Power Cable
LXE offers an external power supply for the desktop cradle. Please refer to the Accessories
section later in this guide.
The external power supply may be connected to either a 120V, 60Hz supply or, outside North
America, to a 230V, 50Hz supply, using the appropriate detachable cord set.
In both cases, connect the external AC supply to a properly grounded source of supply provided
with maximum 15 Amp over current protection (10 Amp for 230V circuits).
Insert the barrel connector into the desk top cradle power jack and push in firmly.
Worldwide AC to DC Adapter Specifications
Figure 3 Worldwide AC Power Supply
Input Power Switch None
Power "ON" Indicator None
Input Fusing Thermal Fuse
Input Voltage 108VAC min - 132VAC max
Input Frequency 47 - 63 Hz
Input Connector North American wall plug, no ground
Output Connector Barrel connector, female, 5.5 x 2.5 x 11.5mm, Center Positive
Output Voltage +9.5VDC, regulated
Output Current 0 Amps min, 1.5 Amps max
Operating Temperature 32° F to 104° F / 0° C to 40° C
Storage Temperature -13° F to 158° F / -25° C to 70° C
Humidity Operates in a relative humidity of 5 – 95% (non-condensing)
Note: The detachable cordset for the Worldwide Power Supply must be ordered separately.