Parameter Name
Number
Min/Max/Default/Units
PTO OFF Interlock Service Brake Pedal
Operated (Depressed)
Page 49
N101 = 1 Required for Mobile Applications
and UltraShift Transmissions
N101
MIN = 0 (OFF)
MAX = 1 (ON)
DEFAUL T= 1 (ON)
Rate to Increase FIC Speed With the
Set/Accel Switch Held
Page 22
N103
MIN = 100 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 350
(RPM/SEC)
Rate to Decrease FIC Speed With the
Set/Accel Switch Held
Page 22
N104
MIN = 100 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 250
(RPM/SEC)
Value to Decrease FIC Speed With a
Resume/Decel Switch Bump
Page 22
N105
MIN = 10 (RPM)
MAX = 1900 (RPM)
DEFAULT = 100 (RPM)
Minimum engine speed during PTO
operation
Page 51
N106
MIN = 650 (RPM)
MAX = 2000 (RPM)
DEFAULT = 650 (RPM)
Value to Increase FIC Speed With a
Resume/Decel Switch Bump
Page 22
N107
MIN = 10 (RPM)
MAX = 1900 (RPM)
DEFAULT = 100 (RPM)
Enable Maximum rate to change PTO
speed after Switch Bump (N081)
Page 50
N109
MIN = 0 (OFF)
MAX = 1 (ON)
DEFAUL T= 0 (OFF)