A SERVICE OF

logo

Parameter Name
Number
Min/Max/Default/Units
PTO ON/OFF Interlock Remote Station
Controls With Transmission-Driven PTO
Page 49
(For stationary applications)
Requirements to enable (N088 = 0)
N079 = 1
N080 = 1
N089 = 0
N088
MIN = 0 (ON)
MAX = 1 (OFF)
DEFAULT= 1 (OFF)
PTO ON/OFF Interlock Neutral
Page 49
With Ultrashift Trans, N089 = 0
N089
MIN = 0 (OFF)
MAX = 1 (ON)
DEFAUL T= 1 (ON)
Value to decrease PTO speed with
Remote Resume/Decel switch bump
Page 51
N090
MIN = 10 (RPM)
MAX = 1000 (RPM)
DEFAULT = 50 (RPM)
Rate to decrease PTO speed with Remote
Resume/Decel switch held
Page 52
N091
MIN = 10 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 200
(RPM/SEC)
Value to increase PTO speed with
Remote Set/Accel switch bump
Page 51
N092
MIN = 10 (RPM)
MAX = 1000 (RPM)
DEFAULT = 50 (RPM)
Rate to increase PTO speed with Remote
Set/Accel switch held
Page 52
N093
MIN = 10 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 250
(RPM/SEC)