
XTP PI 400 Power Injector • Introduction 2
100-240V x.xA
50/60 Hz
1
XTP
PWR
XTP PWR
2
XTP
PWR
XTP PWR
3
XTP
PWR
XTP PWR
4
XTP
PWR
XTP PWR
XTP PI 400
POWER
12V
RxGTx
RS-232 IR
RL
RxTx
-+-+
1
2
AUDIO
ON
AUDIO
RESET
ACT LINK
OVER XTP
OUTPUTS RELAYS
HDMI
OFF
S/PDIF
RL
RxTx
-+-+
1
2
AUDIO
ON
AUDIO
RESET
OUTPUTS RELAYS
XTP IN
HDMI
OFF
S/PDIF
POWER
12V
HDMI
--A MAX
RxGTx
RS-232 IR
RxTx
−+−+
LR
LOOP-THRU
RESET
AUDIO
OFF
ON
AUDIO
LAN
ACT LINK
SIG LINK
XTP OUT
INPUTS
OVER XTP
POWER
12V
HDMI
--A MAX
RxGTx
RS-232 IR
RxTx
−+−+
LR
LOOP-THRU
RESET
AUDIO
OFF
ON
AUDIO
LAN
ACT LINK
SIG LINK
XTP OUT
INPUTS
OVER XTP
Tx Rx
RS-232
12V
1.0A MAX.
POWER
SIG LINK
XTP OUT
RESET
XTP Signal
XTP Signal
XTP Signal
XTP R HDMI
Receiver
XTP T HDMI
Transmitter
XTP T UWP 202
Transmitter
XTP R HDMI
Receiver
XTP PI 400
XTP Power Injector
PS 1210
Desktop Power
Supply
PS 1210
Desktop Power
Supply
PS 1210
Desktop Power
Supply
XTP R HDMI
Receiver
XTP T HDMI
Transmitter
Remote Power
Remote Power
Remote Power
100-240V x.xA
50/60 Hz
1
XTP
PWR
XTP PWR
2
XTP
PWR
XTP PWR
3
XTP
PWR
XTP PWR
4
XTP
PWR
XTP PWR
XTP PI 400
Tx Rx
RS-232
12V
1.0A MAX.
POWER
SIG LINK
XTP OUT
RESET
I
N
P
U
T
S
O
U
T
P
U
T
S
LAN
ACT
LINK
RESET
100-240V
50-60Hz
--A MAX
REMOTE
RS 232/RS422
DISCONNECT POWER
CORD BEFORE
SERVICING
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
IN
IN
XTP CP 4i
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
OUT
OUT
XTP CP 4o
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
RS-232IR
TxRxTxRx
RS-232IR
TxRxTx Rx
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
SIG LINK
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
XTP
PWR
ACT LINK
LAN
IR/RS-232 OVER XTP
POWER
12V
INPUTS
2
--A MAX
RxTx
RS-232 IR
RxTx
1
LAN
SIG LINK
ACT LINK
XTP OUT
OVER XTP
AUDIO
CONTACT
RS-232
Tx Rx
XTP T USW 103
3
1 2 3
RESET
LAN
ACT LINK
SIG LINK
XTP IN
POWER
12V
OUTPUTS
HDMI
--A MAX
RxTx
RS-232 IR
RxTx
−+−+
LR
1
2
OVER XTP
AUDIO
OFF
HDMI AUDIO
ON
S/PDIF
RELAYS
XTP SR HDMI
RESET
REMOTE
RS-232
Tx Rx
LAN
ACT LINK
SIG LINK
XTP IN
POWER
12V
OUTPUTS
HDMI
--A MAX
RxTx
RS-232 IR
RxTx
−+−+
LR
1
2
OVER XTP
AUDIO
OFF
HDMI AUDIO
ON
S/PDIF
RELAYS
XTP SR HDMI
RESET
REMOTE
RS-232
Tx Rx
Extron
XTP CrossPoint 3200
XTP Signal
XTP T USW 103
XTP Transmitter
XTP SR HDMI
XTP Scaling Receiver
XTP SR HDMI
XTP Scaling Receiver
XTP T UWP 202
Transmitter
XTP PI 400
XTP Power Injector
XTP Signal
Remote Power
Remote Power
Remote Power
Remote Power
Figure 2. Typical XTP PI 400 Matrix Application
Features
• Supplies power for up to four remote XTP extenders — Provides power for up to
four XTP transmitters or receivers over the XTP link, eliminating the need for local power
supplies.
• Designed specifically for the high data rates of XTP systems
• No impact on signal quality — Utilization of the power injector does not affect video,
audio, bidirectional RS-232 and IR, and Ethernet signal quality.
• Real-time status LEDs for troubleshooting and monitoring — Front and rear
indicators provide status for each port that is supplying power to an XTP extender.
• UL/c-UL Listed and CE compliant
• 1U, half rack width enclosure
• Internal universal power supply — The 100-240 VAC, 50-60 Hz, international power
supply provides worldwide power compatibility.