XTP PI 400 Power Injector • Reference Information 9
Rack Mounting
Mount the XTP PI 400 to an optional Extron rack shelf. To mount the unit on a rack shelf,
follow the instructions provided with the shelf accessories.
Use 2 mounting holes on
opposite corners.
(2) 4-40 x 3/16"
Screws
NOTE: Using screws longe
r
than 3/16" will damage the
unit and void the warranty.
1U Universal Rack Shelf
Front false
faceplate uses
2 screws.
Half Rack 9.5 inch Box Standard Shelf
1/2 Rack Width Front False
Faceplate
Figure 8. Half Rack Mounting
UL Guidelines for Rack Mounted Devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
XTP PI 400 in a rack.
1. Elevated operating ambient temperature — If the equipment is installed in a closed
or multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the XTP PI 400 in an
environment compatible with the maximum ambient temperature
(Tma = +122 ˚F, +50 ˚C) specified by Extron.
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
3. Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not cause a hazardous condition.
4. Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have an overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (for example, use of power strips).