Wiring Color Code
Electrical Information
Model Evap Fans
Cornice &
Nose Lts
Shelf Lts
Anti-Sweat
Heaters
HP Voltage RLA/LRA
Cond
Fan
Pan Heater Air Sweep Fan
BMD Series-enclosed base
BMD-4 0.6 0.76 0.49 N
1/3 120-1-60 5.6/29 0.58 5.0 0.52
BMD-6 0.6 0.95 0.75 N
1/2 120-1-60 9.4/51 1.4 6.6 0.78
BMD-8 1.2 1.5 0.95 N
3/4 120-1-60 9.8/65 1.7 8.3 1.04
BMD-10 1.2 2.25 1.54 N
1 120-208 1-60 5.7/40 0.94 4.8 1.3
BMD-12 1.8 2.25 1.54 N
1 120-208 1-60 5.7/40 0.94 4.8 1.56
Add 5 amps if a humidification system is added. A separate power source is not needed.
BMD Series-
edestal base or bullet le
s
BMD-4 0.55 0.76 0.49 2.08 1/3 120-1-60 5.6/29 0.58 5.0 0.26
BMD-6 1.1 0.95 1.75 4.16 1/2 120-1-60 9.4/51 1.4 6.6 0.52
BMD-8 1.1 1.5 0.95 4.16 3/4 120-1-60 9.8/65 1.7 8.3 0.52
BMD-10 1.1 1.54 1.54 4.16 1 120-208 1-60 5.7/40 0.94 4.8 0.52
BMD-12 1.65 1.54 1.54 6.24 1 120-208 1-60 5.7/40 0.94 4.8 0.78
Add 5 amps if a humidification system is added. A separate power source is not needed.
BMD Gravit
Coil Series
BMD-G-4 N
0.76 N
N
1/2 120-1-60 7/36 0.7 5.0 0.52
BMD-G-6 N
0.95 N
N
1/2 120-1-60 9.4/51 1.3 6.6 0.78
BMD-G-8 N
0.95 N
N
3/4 120-1-60 11.8/66.3 1.64 8.3 1.04
BMD-G-10 N
1.54 N
N
1 120-1-60 8.2/65 1.7 8.3 1.3
BMD-G-12 N
1.54 N
N
1 120-1-60 11.4/93 1.7 8.3 1.56
BSD Series-enclosed base
BSD-4 0.6 0.76 N
N
1/3 120-1-60 5.6/29 0.58 5.0 0.52
BSD-6 0.6 0.95 N
N
1/2 120-1-60 9.4/51 1.4 6.6 0.78
BSD-8 1.2 1.5 N
N
3/4 120-1-60 9.8/65 1.7 6.6 1.04
BSD-10 1.2 2.25 N
N
1 120-208 1-60 5.7/40 0.94 4.8 1.3
BSD-12 1.8 2.25 N
N
1 120-208 1-60 5.7/40 0.94 4.8 1.56
Add 5 amps if a humidification system is added. A separate power source is not needed.
BSD Series-
edestal base or bullet le
s
BSD-4 0.6 0.76 N
2.08 1/3 120-1-60 5.6/29 0.58 5.0 0.26
BSD-6 0.6 0.95 N
4.16 1/2 120-1-60 9.4/51 1.4 6.6 0.52
BSD-8 1.2 1.5 N
4.16 3/4 120-1-60 9.8/65 1.7 6.6 0.52
BSD-10 1.2 1.54 N
4.16 1 120-208 1-60 5.7/40 0.94 4.8 0.52
BSD-12 1.8 1.54 N
6.24 1 120-208 1-60 5.7/40 0.94 4.8 0.78
Add 5 amps if a humidification system is added. A separate power source is not needed.
BSD Tilt Glass Series
Fans
BSD-T-4 0.6 N
N
N
1/3 120-1-60 5.6/29 0.58 5.0 0.52
BSD-T-6 1.2 N
N
N
1/2 120-1-60 9.4/51 1.4 6.6 0.78
BSD-T-8 1.2 N
N
N
3/4 120-1-60 9.8/65 1.7 6.6 1.04
BSD-T-10 1.2 N
N
N
1 120-208 1-60 5.7/40 0.85 4.8 1.3
BSD-T-12 1.8 N
N
N
1 120-208 1-60 5.7/40 0.85 4.8 1.56
DRY CASES - USE LIGHTING SPECIFICATIONS REMOTE CASES - 20 MINUTES DEFROST EVERY 4 HOURS
Remote Case Data - Electrical 120 Volt Additional Loads for Self-Contained Units
Green------------------------Ground
Black-------------------------Hot
White ------------------------Neutral
Red --------------------------208/220 Only
Brown -----------------------Interlock System
Orange----------------------Thermostat
Orange----------------------Liquid Solenoid
Purple -----------------------Hot Gas Defrost
Purple -----------------------Defrost Terminator
Gray -------------------------Light Switch
Black/White ----------------Pressure Switch
Red ----------Lights
Yellow -------Lights
Blue----------Lights
Secondary Wiring Color Code
SEE BALLAST DIAGRAM FOR EACH CASE
NOTE: Case must be grounded