27
The wire coloured green and yellow must be connected
to the terminal marked with the letter «E» or by the
earth symbol or coloured green and yellow.
The wire coloured blue must be connected to the
terminal marked «N» or coloured black.
The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
WARNING:
A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely. Should the appliance power supply
cable need to be replaced, this must be carried
out by our Service Force Centre.
The power supply cable must be easily accessible
after installing the appliance.
Permanent connection
In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap
of 3mm between the switch contacts and of a type
suitable for the required load in compliance with the
current electrical regulations.
The switch must not break the yellow and green earth
cable at any point.