Installation
39971
16
Electrical Requirements
NOTE: The wiring diagram is located in the
control hood.
Figure 17
120 Volt, 60 Hertz, with 3 Prong Grounding
(Earthing) Plug
The washer is designed to be operated on a separate
branch, polarized three-wire, effectively grounded
(earthed) 120 Volt, 60 Hertz, AC (alternating current),
circuit protected by a 15 ampere fuse, equivalent
fusetron or circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to Figure 18
for determining correct polarity of the wall receptacle.
Do not modify the plug provided with the washer – if
it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
Figure 18
D009I
To reduce the risk of fire, electric shock or
personal injury, all wiring and earthing
MUST conform with the latest edition of the
National Electrical Code, ANSI/NFPA 70, and
such local regulations as might apply. It is
the customer’s responsibility to have the
wiring, fuses and circuit breakers checked
by a qualified electrician to make sure your
home has adequate electrical power to
operate the washer.
W129
WARNING
D009I
DO NOT OVERLOAD CIRCUITS
DO NOT USE ADAPTER
DO NOT USE AN EXTENSION CORD
D090I
1 L1
2 Ground
3 Neutral Side
4 Round Grounding Prong
5 Neutral
STANDARD 120 VOLT, 60 HERTZ, 3 WIRE
EFFECTIVELY GROUNDED CIRCUIT
1
2
3
4
5
120 ± 12
V.A.C.
120 ± 12
V.A .C.
0 V.A.C.