Speed Queen LES37A*F Washer/Dryer User Manual


 
Installation
21
510988
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Exhausting the dryer in hard-to-reach locations can be
accomplished by installing the 521P3 Flexible Metal
Vent Kit, available as optional equipment at extra cost.
The kit comes in two halves that can be attached
separately to the dryer and wall outlet. Once attached,
the dryer can be slid back into position and the two
halves can be connected from the front.
Figure 13
Dryer Airflow
Efficient dryer operation requires proper dryer airflow.
Proper dryer airflow can be evaluated by measuring
the static pressure. Refer to Figure 14.
NOTE: This can be measured with a manometer
placed on the exhaust duct approximately 61 cm
(2 feet) from the dryer. Refer to Figure 14.
Figure 14
D622I
521P3 FLEXIBLE METAL VENT KIT
D622I
D012I
1 Manometer
2 Exhaust Duct
DR012A-IN
1
2
MAXIMUM STATIC
PRESSURE IN
WATER COLUMN
1.5 cm (0.6 in.)
MEASURING STATIC PRESSURE