Speed Queen LES37A*F Washer/Dryer User Manual


 
Installation
510988
18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Location Requirements
Select a location with a solid floor. Dryers installed in
residential garages must be elevated 46 cm (18 inches)
above the floor.
No other fuel burning appliance should be installed in
the same closet with the dryer.
The dryer must not be installed or stored in an area
where it will be exposed to water and/or weather.
The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown in Figure 10.)
Figure 10
**NOTE: For new installations, locate top of wall vent 106.7 cm (42 in.) above floor to make venting easier to connect.
1 Closet Door 3 Centered Air Openings
2 Outer Wall of Enclosure (2 Openings Minimum)
B
A
C
D
A
E
2
FRONT VIEW
(w/o Closet Door)
Area Free Standing/Alcove Installation Closet Installation
A 0 cm (0 in.) 0 cm (0 in.)
B 30.5 cm (12 in.) 30.5 cm (12 in.)
C Not Applicable 5.1 cm (2 in.)
D 5.1 cm (2 in.) 5.1 cm (2 in.)
E 30.5 cm (12 in.) 30.5 cm (12 in.)
F Not Applicable 7.6 cm (3 in.)
G* Not Applicable
260 cm
2
/open (40 in
2
/open)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)
SIDE VIEW
A
FRONT VIEW
(Closet Door)
**106.7 cm
(42 in.)
F
F
1
3 (G)
D317I