Speed Queen LES37A*F Washer/Dryer User Manual


 
Installation
510988
16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
240 Volt, 60 Hertz, 3-Wire
NOTE: The wiring diagram is located inside the
control hood.
Grounding Instructions
This dryer must be connected to a grounded metal,
permanent wiring system; or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or
lead on the dryer.
Figure 8
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer’s responsibility to have the wiring
and fuses checked by a qualified electrician
to make sure your home has adequate
electrical power to operate the dryer.
W113
WARNING
D816I
1 3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)
4 Metallic or Non-Metallic Sheathed Cable
(Copper Wire Only)
5 Pigtail to Dryer (Refer to NOTE above)
2 30 Ampere Fuses or Circuit Breaker 6 Neutral
3 Neutral Wire 7 Terminal Block in Dryer
NOTE: The power cord (pigtail) is NOT supplied with the electric dryer.
Type of pigtail and gauge of wire must conform to local codes and
instructions.
The method of wiring the dryer is optional and subject to local code
requirements.
NOTE: Connect the dryer to the power supply with the MAXIMUM RATED
VOLTAGE listed on the nameplate.
1
2
3
4
5
6
7
POWER SUPPLY POWER SUPPLY
INTERMEDIATE
FUSE BOX (May
be omitted if
service entrance
box is fused)
WALL RECEPTACLE
PIGTAIL CONNECTION
L1 L2 L1 L2
DIRECT CONNECTION
INTERMEDIAT
E
SHUT-OFF BOX
(May or may no
t
be fused)
120 ± 12
V.A.C.
A typical
30-Amp
Three-wire
Receptacle
NEMA Type
10-30R
120 ± 12
V.A.C.
240 ± 12
V.A .C .
NOTE: Use COPPER WIRE only.
Shorter than 4.5 m (15 ft.) use 10 A.W.G.
Longer than 4.5 m (15 ft.) use 8 A.W.G.