Smeg WDI12C1 Washer/Dryer User Manual


 
EN
27
3. Pull out the drain hose “A”.
Attention: if the hose is hot it means the water is hot or boiling. Place a
tray on the floor and remove the plug “B” to drain the water.
Depending on the quantity of water, it may be necessary to empty the
tray several times.
When no more water comes out, push the hose back in and screw
back the plug “B”.
4. Unscrew the cover of the pump “D” by turning it anti-clockwise.
Clean the pump body and remove any foreign bodies.
Check the inside “E” and make sure the impeller turns freely. If there are
any foreign bodies, remove them.
5. Screw the pump cover back on.
Fix the drain hose by snapping the plug into place «C».
Depending on the model, put back the cover as follows:
MODEL A – Insert the lower part of the cover first. Then secure it by turning the plastic buttons a quarter
turn clockwise.
The slots in the buttons must be horizontal.
MODEL B – Insert the lower part of the cover first and then push it towards the base plate until it clicks
into place.
7.5 CLEANING THE DETERGENT TRAY
Keep the detergent tray free from scale.
To simplify this operation, completely remove the detergent tray (pull it out
as far as it will go, lift it slightly and then pull fairly vigorously).
Remove the traps «B» (there are two traps if the machine is not fitted with a
cover for the bleach compartment) and clean with hot water.
Put back the traps and remove any residues of detergent before putting the
tray back.
7.6 CLEANING THE WATER INLET FILTER
The machine is fitted with a filter for protecting the water inlet valves.
The filter is fitted the gas thread of the inlet hose connected to the tap
Clean the filter if no water or insufficient quantities of water enter the washing machine.
To do this, proceed as follows:
Remove the plug from the socket to disconnect the machine from the
electrical power supply.
Turn off the water tap.
Unscrew the inlet hose from the tap.
Remove the filter from the inlet hose gas thread.
Clean the filter with water and a brush.
When screwing the inlet hose back on to the tap, make sure the filter is correctly positioned.