5. Device demands more than 200 Watts continuous
power.
CycleinverterpowerOFFandON.
If problem persists, use a larger inverter or a smaller
device.
6. Inverter is too hot.
Increase ventilation to inverter.
Move inverter to a cooler area.
Reduce the power consumption of the device.
PROBLEM: Inverter Does Not Turn On
Reason/Solution
1. Poor contact at terminals.
Unplug and reinsert PID-200. Also check auxiliary plug
for debris or try in another socket.
2. Fuse is blown.
A blown fuse is usually caused by reverse polarity or
a short circuit within the inverter. To replace, contact a
qualiedservicetechnicianwhowilldiagnosetheinverter
and replace the fuse with the appropriate replacement.
3. Inverter may be defective.
See warranty and call Customer Service 800-621-5485
(Hours:7a.m.–4:30p.m.CST).
4. Power consumed by load may be too high.
Cut-off unit. Unplug load and cut unit back on without
load and see if it works.