Pitney Bowes W863 Washer/Dryer User Manual


 
7SV61228 Rev. A
W983 Stacker/W863 Dryer Operating Guide
The illustrations above show the Stacker connectors and fuses.
1 Trip Sensor connector - This is where the cable from the
Stack ing full arm is con nect ed. This activates when the Stacker
is full.
2 Printer Interface connector - This is where the interface cable
coming from the printer is connected.
3 Circuit Breaker 1.0 A switch - This is a switch that “toggles”
if pieces jam in the Stacker, causing the Stacker to power off
au to mat i cal ly. After the jam is cleared, you must press this switch
to reset the Stacker before you can resume operation.
4 Fuses - Two 1.6 Amp Slo Blow 250 VAC fuses.
5 Dryer 11.5 A 120 VAC - This is an 11.5 amp convenience outlet
to be used with the op tion al ink Dryer (W863).
6 Power 12.0 A 120 VAC receptacle - This is where the input
power cord is con nect ed for the Stacker.
1
23
44
5
6
Connector and Side Panels
Stacker_Dryer Op Guide Book.indb 7Stacker_Dryer Op Guide Book.indb 7 3/30/2004 10:26:44 AM3/30/2004 10:26:44 AM