Electrical connection
For IRL only
This tumble dryer is supplied ready for
connection to an a.c. single phase
230 V, 50 Hz supply. The rated load is
2.7 kW. The machine is supplied with a
2 m long mains cable with moulded
plug and the fuse rating is 13 A.
The appliance should be connected up
only by a qualified electrician, in ac-
cordance with national and local safety
regulations.
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings ident-
ifying the terminals in your plug, pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol z or
coloured green or green and yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter L or coloured red.
WARNING
THIS APPLIANCE MUST BE EARTHED.