Maytag MDG31 Clothes Dryer User Manual


 
113430-10 Telephone: (641) 787-7000 25
Data Label Information _____________________________________________________________
Standard Label
When contacting Maytag, the information on the data label is required to ensure proper service/parts assistance. The data label
is located at the upper left rear of the dryer behind the back guard.
1. Model Number – This describes the style of dryer and type of heat (gas, electric, or steam).
2. Serial Number – Allows the manufacturer to gather information on your particular dryer.
3. Type of Heat – This describes the type of heat for your particular dryer, gas (either natural gas or L.P. gas), electric, or steam.
4. Heat Input (For Gas Dryers) – This describes the heat input in British thermal units per hour (Btu/hr) or kilowatts (kW).
5. Orifice Size (For Gas Dryers) – Gives the number drill size used.
6. Electric Service – This describes the voltage and current rating for a particular model.
7. Gas Manifold Pressure (For Gas Dryers) – This describes the manifold pressure taken at the gas valve tap.
CE Label
Note
Do not obstruct the flow of combustion and
ventilation air. Check back draft dampers in the
exhaust ductwork. Inspect and remove any lint
accumulation, which can cause the damper to bind or stick.
A back draft damper that is sticking partially closed can
result in slow drying and shutdown of heat circuit safety
switches or thermostats.
When cleaning the dryer cabinet(s), avoid using harsh
abrasives. A product intended for the cleaning of
appliances is recommended.
7 Days After Installation
and Every 12 Months Thereafter
A competent professional should inspect bolts, nuts, screws,
setscrews, grounding connections and nonpermanent gas
connections (unions, shutoff valves, and orifices). Belts
should be examined. Cracked or seriously frayed belts
should be replaced. Complete an operational check of
controls and valves. Complete an operational check of all
safety devices (lint door/drawer switch, door switches, sail
switch, and hi-limit thermostats).
!