Maytag MAH22PDAGW0 Washer User Manual


 
14
5. Quick Overview Test - With the entire display flashing, this
cycle is started by pressing the WOOLENS key pad. This
cycle provides a quick verification that the cold and hot water
valves, dispensers, and pump motor are working, as well as
actuator dispenser movement. It also includes door lock,
drain, and spin operations.
Pressing the DELICATES AND KNITS key pad will exit diagnostic
mode and cancel a diagnostic cycle in process.
DIAGNOSTIC CODES
If the set-up mode is entered and one of the following has
occurred, the appropriate diagnostic code will be in the display.
d5 Blocked coin 1 or coin drop control circuit failure (coin
r
ecognition and price display disabled while blockage
persists). PN Models Only: Set-up mode J. should be
set to _d (or Ed if in free operation mode) to eliminate
coin related diagnostic codes.
d9 Low voltage detected for 8 seconds.
d13 Blocked coin 2 or coin drop control circuit failure
(coin recognition and price display disabled
while
blockage persists).
F20 Slow Fill. The washer will not detect water input for
4 min. Pressure switch failure or no water inlet. This
code is
reported as d8 on d7.
F22 The door is not able to lock. Door lock error or
someone trying to start the washer, by pressing the
door switch with the finger. This code is reported as
d17 on Accu Trac.
(For different code consult service personnel)
WASHER HELP MODE
This mode is entered by pressing the PERMANENT PRESS key
pad while in special pricing option mode 2.XX (or while dAS
displays if operating with Maytag Data Acquisition set-up).
In help mode, other display symb
ols and elements are mapped
to reflect the state of various inputs a
nd outputs as follows:
Display Symbol Description
Wash Water sensed at wash level.
*
Low voltage present (below about
90 VAC).
° (Circle above digit) Door closed.
DOOR LOCKED Door sensed locked.
COLD Cold water relay on.
HOT Hot water relay on.
OR Door unlock.
AVAILABLE Drain pump ON.